<p>Detalii produs</p><p>Characteristics</p><p>Measured parameter: TEMP, ECG, NIBP, SpO2</p><p> </p><p>Applications: clinical, transport</p><p> </p><p>Configuration: portable</p><p> </p><p>Other characteristics: continuous, wireless, with touchscreen</p><p> </p><p>Features</p><p>• 8” color TFT LCD Screen (touch screen optional)</p><p>• Portable, lightweight and sturdy design</p><p>• Flexible parameters configuration for different clinical environments</p><p>• Rechargeable Li-ion Battery (up to 12 hours uninterruptable work)</p><p>• Big font and font color display setting</p><p>• Spot-check and continuous monitoring mode</p><p>• Selectable for Adult, Pediatric and Neonatal patients</p><p>• Wired/Wireless CMS, support HL7 protocol to HIS</p><p>• Barcode scanner support</p><p>• Thermal recorder support</p><p>• Graphical & tabular trend review</p><p>• 48 hours holographic wave review for each patient (stored in SD card)</p><p> </p><p>Configuration 1</p><p>SpO2 + NIBP, Li-ion battery</p><p>Optional</p><p>Masimo/Nellcor SpO2, Quick Temp, Barcode scanner</p><p> </p><p>Configuration 2</p><p>SpO2+NIBP+ECG+TEMP, Li-ion battery</p><p>Optional</p><p>Masimo/Nellcor SpO2, EtCO2, Quick Temp, Barcode scanner, Thermal Recorder</p><p> </p><p>TEHNICAL SPECIFICATIONS</p><p> </p><p>Display</p><p>8” color TFT LCD Screen, resolution: 800 x 600</p><p> </p><p>ECG</p><p>Lead type:</p><p>3-lead: I, II, III</p><p>5-lead: I, II, III, aVR, aVL, aVF, V</p><p>Display sensitivity:</p><p>2.5 mm/mV (×0.25), 5 mm/mV (×0.5),</p><p>10 mm/mV (×1.0), 20 mm/mV (×2.0)</p><p>Wave sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s</p><p>Bandwidth:</p><p>Diagnostic mode: 0.05Hz~100Hz</p><p>Monitor mode: 0.5Hz~40Hz</p><p>Surgery mode: 1Hz~20Hz</p><p>Strong filter mode: 5Hz~20Hz CMRR >100dB</p><p>Notch: 50/60 Hz notch filter can be set to on or off</p><p>Differential input impedance >5 MΩ</p><p>Electrode polarization voltage range: ±400 mV</p><p>Baseline recovery time <3 s after defibrillation (in monitor and surgery mode)</p><p>Calibration signal: 1 mV (peak - peak), accuracy ±3%</p><p> </p><p>RESP</p><p>Measurement method: Thoracic electrical</p><p>bioimpedance</p><p>Measuring lead: Lead I, II</p><p>Wave gain: ×0.25, ×0.5, ×1, ×2</p><p>Respiratory impedance range: 0.5-5 Ω</p><p>Baseline impedance: 500-4000 Ω</p><p>Gain: 10 grades</p><p>Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s</p><p> </p><p>TEMP</p><p>Measurement method: Thermistor</p><p>Measuring range: 5~50 °C (41~122 °F)</p><p>Resolution: 0.1 °C</p><p>Measurement accuracy: ±0.1 °C</p><p> </p><p>Recorder (optional)</p><p>Built-in, Thermal dot array</p><p>Horizontal resolution: 16 dots/mm (25 mm/s paper speed)</p><p>Vertical resolution: 8 dots/mm</p><p>Paper speed: 25 mm/s, 50 mm/s</p><p>Number of waveform channels: 3</p><p> </p><p>NIBP</p><p>Measurement method: Automatic</p><p>oscillometric method</p><p>Operating mode: Manual, automatic,</p><p>continuous</p><p>Measurement unit: mmHg/kPa selectable</p><p>Typical measurement time: 20~40 s</p><p>Measurement type: Systolic, Diastolic, Mean</p><p>Measurement range (mmHg)</p><p>Range of Systolic pressure:</p><p>Adult 40-270</p><p>Pediatric 40-230</p><p>Neonatal 40-135</p><p>Range of Diastolic pressure:</p><p>Adult 10-210</p><p>Pediatric 10-150</p><p>Neonatal 10-100</p><p>Range of Mean pressure:</p><p>Adult 20-230</p><p>Pediatric 20-165</p><p>Neonatal 20-110</p><p>Measurement accuracy</p><p>Maximum average error: ±5 mmHg</p><p>Maximum standard deviation: 8 mmHg</p><p>Resolution: 1 mmHg</p><p>Interval: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120,</p><p>180, 240, 480 minutes</p><p>Overpressure protection: Software and</p><p>hardware, double safety protection</p><p>Cuff pressure range: 0-280 mmHg</p><p> </p><p>Standard SpO2</p><p>Measurement range: 0-100%</p><p>Resolution: 1%</p><p>Accuracy: ±2% (70-100%, Adult/Pediatric); ±3% (70-100%, Neonate); 0-69%, unspecified</p><p>Refreshing Rate: 1s</p><p>Masimo SpO2 (optional)</p><p>Measurement range: 0-100%</p><p>Resolution: 1%</p><p>Accuracy:</p><p>±2% (70-100%, Adult/Pediatric), non-motion, low</p><p>±3% (70-100%, Neonate, non-motion);</p><p>±3% (70-100%, motion);</p><p>0-69%, unspecified</p><p>Refreshing Rate: 1s</p><p> </p><p>Infrared Ear Thermometer (optional)</p><p>Displayed range: 34~42.2 °C (93.2~108 F°)</p><p>Operation ambient temperature range:</p><p>10~40 °C (50~104 °F)</p><p>Accuracy for displayed temperature range:</p><p>≥35 °C (95.9 °F) ~ ≤42.2 °C (107.6 °F) range ±0.2 °C (0.4 °F)</p><p><35 °C (95.9 °F) ~ ≥34 °C (93.2 °F) range ±0.3 °C (0.5 °F)</p><p> </p><p>Phasein IRMA™ Sidestream CO2 (optional)</p><p>Warm-up time: Full accuracy within 10 seconds</p><p>Sampling flow rate: 50 ml/min (+/-10/min)</p><p>Accuracy: ± (0.2% +2% of the reading)</p><p>Measurement Range: 0 -15%</p><p>Rise time: 200 ms, typical at 50 ml/min flow rate</p><p>Total response time: within 3 seconds</p><p>(with 2m Momoline sampling line)</p><p>AWRR Range: 0-150 bpm</p><p>AWRR Accuracy: ±1 breath</p><p> </p><p>Phasein IRMA™ Mainstream CO2 (optional)</p><p>Measurement Range: 0-15%</p><p>Warm-up time: Full accuracy within 10 seconds</p><p>Accuracy: ± (0.2% +2% of the reading)</p><p>AWRR Range: 0-150 bpm</p><p>AWRR Accuracy: ±1 breath</p><p> </p><p>Operation Environment</p><p>Power: AC 100-250 V, 50/60 Hz</p><p>Temperature: 0-40 °C</p><p>Humidity: 15-85%</p><p>Patient Range: Adult, Pediatric, Neonate</p><p> </p><p>Va rugam sa ne contactati pentru oferta de pret!</p><p>Echipa SANTIMPEX</p><p> </p><p> </p><p> </p><p><a href="http://www.santimpex.ro/ati/pavo-monitor-functii-vitale">http://www.santimpex.ro/ati/pavo-monitor-functii-vitale</a></p>
SANTIMPEX SRL Deva