SANTIMPEX - Deva - Echipamente ATI » CETUS x15 Critical Care Patient Monitor

Detalii

<p>Detalii produs</p><p>Features</p><p>• 15.6” High resolution TFT LCD Touch screen</p><p>• 10 waveform display, up to 12-lead ECG analysis</p><p>• Powerful calculation (Hemodynamic, Drug Dose, Oxygenation, Ventilation)</p><p>• Pacemaker detection</p><p>• ST &amp; arrhythmia analysis</p><p>• SpO2 support PVI and PI, low perfusion 0.2%</p><p>• Aspect BISx module, NMT (Organon TOF-Watch®) module optional</p><p>• Wired/Wireless CMS, support HL7 protocol to HIS</p><p>• SpO2 pulse-tone modulation (Pitch Tone)</p><p>• VGA support external display</p><p>• Graphical &amp; tabular trend review (120 hours)</p><p>• 48 hours full disclosure wave review for each patient (stored in SD card)</p><p>&nbsp;</p><p>Configuration</p><p>5-lead ECG, SpO2, NIBP, TEMP, Resp, PR; Li-ion battery</p><p>&nbsp;</p><p>Optional</p><p>Touch-Screen, 12-lead ECG, Masimo/Nellcor SpO2, IBP, C.O., EtCO2, Multi-Gas, BIS, NMT, VGA, Thermal Recorder, Wired/Wireless CMS</p><p>&nbsp;</p><p>TEHNICAL SPECIFICATIONS</p><p>&nbsp;</p><p>Display</p><p>15.6” TFT (touch screen optional)</p><p>Resolution: 1366 x 768</p><p>Number of traces: 12 waveforms</p><p>&nbsp;</p><p>I/O</p><p>LAN: 1 standard RJ45 port</p><p>WLAN: IEEE 802.11b/g/n</p><p>USB: 2 USB connectors</p><p>SD: 1 SD card socket</p><p>VGA: 1 VGA monitor connector</p><p>Output: 1 connector for Nurse call, Defib Sync Analog Output</p><p>&nbsp;</p><p>ECG</p><p>Lead type: 3-lead, 5-lead,12-lead</p><p>ECG waveform: 2 channels, 7 channels, 12 channels</p><p>Display sensitivity: 2.5 mm/mV (×0.25), 5 mm/mV (×0.5), 10 mm/mV (×1.0), 20 mm/mV (×2.0)</p><p>Wave sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s</p><p>Bandwidth</p><p>Diagnostic mode: 0.05 Hz~100 Hz</p><p>Monitor mode: 0.5 Hz~40 Hz</p><p>Surgery mode: 1 Hz~20 Hz</p><p>Strong filter mode: 5Hz~20 Hz</p><p>CMRR&gt;100 dB</p><p>Notch: 50/60 Hz notch filter can be set to on or off</p><p>Differential input impedance &gt;5MΩ</p><p>Electrode polarization voltage range: ±400mV</p><p>Baseline recovery time &lt;3s after defibrillation (in monitor and surgery mode)</p><p>Calibration signal: 1 mV (peak - peak), accuracy ±3%</p><p>&nbsp;</p><p>RESP</p><p>Measurement method: Thoracic electrical bioimpedance</p><p>Measuring lead: Lead I, II</p><p>Wave gain: ×0.25, ×0.5, ×1, ×2</p><p>Respiratory impedance range: 0.5-5 Ω</p><p>Baseline impedance: 500-4000 Ω</p><p>Gain: 10 grades</p><p>Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s</p><p>&nbsp;</p><p>TEMP</p><p>Accuracy: ±0.1 or ±0.2 °F (without probe)</p><p>Measurement range: 5~50? (41~122 °F)</p><p>Channel: Two channels</p><p>Resolution: 0.1?</p><p>Parameters:?T1, T2 and TD</p><p>&nbsp;</p><p>SpO2</p><p>Measurement range: 0-100%</p><p>Resolution: 1%</p><p>Accuracy: ±2% (70-100%, Adult/Pediatric); ±3% (70-100%, Neonate); 0-69%, unspecified</p><p>Refreshing Rate: 1s</p><p>&nbsp;</p><p>Masimo SET® SpO2(Optional)</p><p>Measurement range: 0-100%</p><p>Resolution: 1%</p><p>Accuracy: ±2% (70-100%, Adult/Pediatric, non-motion, low prefusion); ±3% (70-100%, Neonate, non-motion); ±3% (70-100%, motion); 0-69%, unspecified</p><p>Refreshing Rate: 1s</p><p>&nbsp;</p><p>Pulse Rate</p><p>Range: 30~300 bpm</p><p>Resolution: 1 bpm</p><p>Accuracy: ±2bpm (non-motion); ±5bpm (motion)</p><p>Refreshing rate: 1s</p><p>&nbsp;</p><p>NIBP</p><p>Measurement method: Automatic oscillometric method</p><p>Operating mode: Manual, automatic, continuous</p><p>Measurement unit: mmHg/kPa selectable</p><p>Typical measurement time: 20~40 s</p><p>Measurement type: Systolic, Diastolic,</p><p>Mean Measurement range (mmHg)</p><p>Range of Systolic pressure:</p><p>Adult 40-270</p><p>Pediatric 40-200</p><p>Neonatal 40-135</p><p>Range of Diastolic pressure:</p><p>Adult 10-210</p><p>Pediatric 10-150</p><p>Neonatal 10-95</p><p>Range of Mean pressure:</p><p>Adult 20-230</p><p>Pediatric 20-165</p><p>Neonatal 20-105</p><p>Measurement accuracy</p><p>Maximum average error: ±5 mmHg</p><p>Maximum standard deviation: 8 mmHg</p><p>Resolution: 1 mmHg</p><p>Interval: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 minutes</p><p>Overpressure protection: Software and hardware, double safety protection</p><p>Cuff pressure range: 0-280 mmHg</p><p>&nbsp;</p><p>IBP (Optional)</p><p>Channel: 2-channel or 4-channel</p><p>ART: 0 to 300 mmHg</p><p>PA: -6 to 120 mmHg</p><p>CVP/RAP/LAP/ICP: -10 to 40 mmHg</p><p>Measurement range: P1/P2 -50 to 300 mmHg</p><p>Resolution: 1mmHg</p><p>Accuracy: ±2% or ±1mmHg, whichever is greater (without sensor)</p><p>Sensitivity: 5uV/mmHg/V</p><p>Impedance range: 300 to 3000 Ω</p><p>&nbsp;</p><p>C.O. (Optional)</p><p>Method: Thermodilution</p><p>Range: C.O.: 0.2 to 20 L/min</p><p>TB: 23 to 45 ?</p><p>T1: -1 to 27?</p><p>Accuracy: C.O.: ±5% or ±0.1L/min, whichever is greater TB, T1?±0.5? (without sensor)</p><p>&nbsp;</p><p>Standard Mainstream CO2 (Optional)</p><p>Measurement range: 0-19.7%, 150 mmHg, or 0-20 kPa</p><p>Resolution: 0.1 mmHg</p><p>Measurement accuracy:</p><p>0-40 mmHg: ± 2 mmHg</p><p>41-70 mmHg: ± 5% of reading</p><p>71-100 mmHg: ± 8% of reading</p><p>101-150 mmHg: ± 10% of reading</p><p>Respiration rate: 3-150 bpm</p><p>Respiration rate accuracy: 1 ±1bpm</p><p>Warm-up time: 97% within 8 s, full accuracy within 20 s</p><p>&nbsp;</p><p>Standard Sidestream CO2 (Optional)</p><p>Measurement rage: 0-20% (0-150 mmHg)</p><p>Accuracy:</p><p>&lt; 5.0% CO 2: ± 2 mmHg</p><p>&gt; 5.0% CO 2: &lt; 6% of reading</p><p>Respiration rate: 2~150 BPM</p><p>Respiration rate accuracy: 1% ±1BPM</p><p>Warm-up time: 97% within 45 s, full accuracy within 10 min.</p><p>Rise times (t 10-90%): About 100 ms, when flow is 100 ml/min, adult water trap, 1.5 m sampling tube</p><p>Delay time: &lt;3 sec when flow is 100 ml/min, adult water trap, 1.5 m sampling tube</p><p>&nbsp;</p><p>Recorder (Optional)</p><p>Built-in, Thermal dot array</p><p>Horizontal resolution: 16 dots/mm (25 mm/s paper speed)</p><p>Vertical resolution: 8 dots/mm</p><p>Paper speed: 25 mm/s, 50 mm/s</p><p>Number of waveform channels: 3</p><p>&nbsp;</p><p>Phasein ISA Sidestream CO2 (Optional)</p><p>Warm-up time: Full accuracy within 10 seconds</p><p>Sampling flow rate: 50ml/min(+/-10/min)</p><p>Measurement Range: 0-25%</p><p>Accuracy:</p><p>0~15% (±0.2% of the reading)</p><p>15~25%, unspecified</p><p>Rise time: 200 ms, typical at 50 ml/min flow rate</p><p>Total response time: within 3 seconds (with 2 m Momoline sampling line)</p><p>AWRR Range: 0-150 bpm</p><p>AWRR Accuracy: ±1 breath</p><p>&nbsp;</p><p>Phasein IRMA™ Mainstream CO2 (Optional)</p><p>Measurement Range: 0-25%</p><p>Accuracy:</p><p>0~15% (±0.2% of the reading)</p><p>15~25%, unspecified</p><p>Warm-up time: Full accuracy within ‚ 10 seconds</p><p>AWRR Range: 0-150 bpm</p><p>AWRR Accuracy: ±1 breath</p><p>&nbsp;</p><p>Phasein IRMA™ AX+ Mainstream Multi-gas (Optional)</p><p>Gas: CO2, N2O, HAL, ISO, ENF, SEV, DES with automatic identification</p><p>Warm-up time: Full accuracy within 20 seconds for IRMA</p><p>AX+ CO2 Accuracy:</p><p>0-10%: ± (0.2%+2% of the reading)</p><p>0-15%: ± (0.3%+2% of the reading)</p><p>N2O Accuracy:</p><p>0-100%: ± (2%+2% of the reading)</p><p>HAL, ISO, ENF:</p><p>0-8%: ± (0.15%+5% of the reading)</p><p>SEV:0-10%: ± (0.15%+5% of the reading)</p><p>DES:0-22%: ± (0.15%+5% of the reading)</p><p>Agent identification time: &lt;20 s (typical &lt;10 s)</p><p>AWRR range: 0-150 bpm</p><p>AWRR accuracy: +/-1bpm</p><p>Apnea time: 20~60 s</p><p>&nbsp;</p><p>Aspect BISx module (Optional)</p><p>Parameter Measurement:</p><p>BC: 0~30 (Only limited to the combined use of an external sensor with a BIS module)</p><p>EMG: 30~55 dB (bar chart) with intensity between 30 dB and 80 dB (tendency chart)</p><p>BIS: 0~100</p><p>SQI: 0%~100%</p><p>SR: 0%~100%</p><p>SEF: 0.5 Hz~30 Hz</p><p>TP: 40~100 Db</p><p>EEG Measurement:</p><p>Input impedance &gt;5 MΩ</p><p>Noise (RTI) &lt;2 μV (0.25~50 Hz)</p><p>Input signal range: ±1 Mv</p><p>EEG bandwidth between: 0.25 Hz~110 Hz</p><p>&nbsp;</p><p>NMT Tof-Watch® SX (Optional)</p><p>Microprocessor-controlled</p><p>Stimulation Mode: TOF, TOFS, PTC,</p><p>1 Hz Twitch, 0.1 Hz Twitch, DBS DBS3.3 and</p><p>3.2 (Double Burst), Tetanic Stimulation (Burst),</p><p>5s – 50 Hz or 100 Hz</p><p>Output (accuracy ±5% of full scale value)</p><p>Surface electrodes:</p><p>Constant current, 0-60 mA (0-12/18μC) up to 5 KOhm.</p><p>Monophasic, 200 μs or 300 μs pulse width</p><p>Needle electrodes:</p><p>Constant current,0-6 mA (0-0.24 μC) up to 5 KOhm.</p><p>Monophasic, 40 μs pulse width</p><p>Acceleration transducer: Accuracy ±5% of full scale value</p><p>Temperature sensor: Range 20.0-41.5°C (accuracy ±5 °C)</p><p>&nbsp;</p><p>Operation Environment</p><p>Power: AC 100-250 V, 50/60 Hz</p><p>Temperature: 5-40 °C</p><p>Humidity: &lt;80%</p><p>Patient Range: Adult, Pediatric, Neonate</p><p>&nbsp;</p><p>&nbsp;</p><p>Va rugam sa ne contactati pentru oferta de pret!</p><p>Echipa SANTIMPEX</p><p>&nbsp;</p><p>&nbsp;</p><p><a href="http://www.santimpex.ro/ati/cetus-x15-critical-care-patient-monitor">http://www.santimpex.ro/ati/cetus-x15-critical-care-patient-monitor</a></p>


Vezi si alte Produse / Servicii - SANTIMPEX SRL